packages

units

0.1.0공식

Physical quantities with units: dimensions checked at compile time, SI and common units, parsing, conversion, CODATA constants

공개 · MIT OR Apache-2.0 · 의존성 0개

공식 패키지: use units::..;만 쓰면 첫 빌드가 추가합니다. 또는:

nabi add units

그다음 코드에서

use units::{Measure, UnitError};
deps: {
    "units": Dep::version("^0.1.0"),
},

CI packages.nabi-lang.org License: MIT OR Apache-2.0

Physical quantities with units for Nabi. A Quantity carries its dimension, the exponents of the seven SI base quantities, in its type: a formula that adds a length to a time, or passes an energy where a force goes, does not compile, and the check costs nothing when the program runs. Units read at run time ("km/h", "kg*m/s^2") go through DynUnit and Measure, which check the dimension when they run and throw a UnitError that names both sides and the factor between them.

Add it

nabi add units

Needs Nabi 0.1 or later. Pure Nabi: every target works, wasm included.

Usage

use units::kinds::{Energy, Length, Mass, Time, Velocity};
use units::symbols::{h, km, mi, kg, m, s²};

fn speed(d: Length, t: Time) -> Velocity { d / t }
fn kinetic(mass: Mass, v: Velocity) -> Energy { 0.5 * mass * v.squared() }

let v = speed(42.195km, 2h);
println(v);                    // 5.860416666666667 m/s
println(v → km / h);           // 21.0975 km/h
println(5km → mi);             // 3.1068559611866697 mi
println(kinetic(2kg, 3m / 1s)); // 9 J
let newton = kg * m / s²;      // a static unit; prints `kg·m/s²`

Number suffixes (3km, 9.81m / 1s / 1s, 5kΩ, 2μF, 20degC) give quantities; units::symbols has the same units as constants for .to(..), .value_in(..) and unit algebra. Values are held in coherent SI units, and a quantity prints with its SI unit, simplified to a named one where that is shorter (N, J/K, W/(m·K)).

let p = 2kN / 4cm²;            // 5000000 Pa
// let mistake = 3m + 2s;      // does not compile: `+` needs one dimension

Temperatures on scales with an offset are readings, not amounts: two readings subtract to an interval in kelvin, an interval adds to a reading, and two readings do not add.

use units::symbols::degF;

let t = 20degC;
println(t → degF);             // 68 °F
println(30degC - 20degC);      // 10 K
println(t + 5K);               // 25 °C
// 20degC + 10degC              does not compile

Units known only at run time:

use units::{Measure, UnitError};

let g = try Measure::parse("9.81 m/s^2");
println(try g.to_str("ft/s^2"));   // 32.18503937007874 ft/s²
try g.to_str("s") catch e: UnitError {
    println(e); // cannot convert m/s² (acceleration, L·T⁻²) to s (time, T): the dimensions differ; divide by a jerk (m/s³) first
};

CODATA constants are quantities too, with their uncertainties as data:

use units::constants::{c, h, k_B, lookup};

println(h * c / 500nm);            // photon energy, in J
println(k_B * 25degC.absolute());  // thermal energy at room temperature
println((lookup("G") ?? panic("G")).uncertainty); // 0.0000000000000015

What is in it

ItemContents
Quantity<V, L, M, T, I, K, N, J>a value of type V in SI units; the seven exponents are length, mass, time, current, temperature, amount, luminous intensity. * / + -, comparisons, √, .squared(), .powi::<n>(), .to(u), .value_in(u), f"{q:.3}", f"{q:.2e}", .format(spec) for a spec chosen at run time, .measure()
kindsnames for 46 dimensions: Length, Velocity, Force, Pressure, Entropy, ...; each takes the value type, Length<f32>, f64 when left out
symbolsabout 170 unit constants: m, km, μm, inch, mi, kg, lb, s, ms, h, Hz, N, J, kWh, eV, W, hp, Pa, bar, atm, psi, V, Ω, F, T, K, mol, deg, kn, mph, m², s², s⁻¹, ...; degC, degF, degR, kelvin scales
Unit<..>a static unit: symbol and scale; * and / combine units, .of(x), .array(a)
DynUnit, Measureunits and values with a run-time dimension: DynUnit::parse, Measure::parse, .to, .to_str, .fixed()
Dima dimension as a value: algebra, .symbol(), .ascii(), .name()
Temperature, temperature::Scalereadings on the Kelvin, Celsius, Fahrenheit and Rankine scales
constantsc, h, hbar, e, k_B, N_A, R, F, sigma, G, alpha, mu_0, epsilon_0, m_e, m_p, m_n, m_u, a_0, R_inf, ...; codata(), lookup
unit::catalogue, unit::prefixthe unit catalogue (NIST SP 811 factors) and the 24 SI prefixes, quecto to quetta
literalsnumber suffixes (feature literals, on by default)
opsq → u conversion and x° degrees (feature ops, on by default)
UnitErrorwhat went wrong: Mismatch, Unknown (with a suggestion), Syntax, Value

Reading a type error

A static mismatch names the kinds, expects Velocity, found Length. A dimension with no name in kinds shows its exponents in order L, M, T, I, K, N, J: Quantity<f64, 1, 0, 1, 0, 0, 0, 0> is a length times a time (m·s).

Operators

OperatorMeaningLevel
q → u (U+2192)q.to(u): the quantity in unit u; a Measure on the right gives a Result|: a + b → km converts the sum
x° (U+00B0)x degrees as an angle in radians, a dimensionless quantitypostfix ?: -30° is -(30°)
√qsquare root; every exponent must be even, else it does not compilecore's prefix √
q ** na Measure: n is a value, so the dimension is too. q.powi::<n>() and q.squared() stay static**

Literals and other packages

A suffix is a name, so m², μs, kΩ, 2bar and 1oz work and % or °C do not (percent, degC). No suffix may start with e (2e3 is an exponent): the electronvolt has keV, MeV, GeV, TeV but no eV suffix (eV.of(2.0)).

The signal package registers hz, khz, mhz, ms and us as plain f64 numbers at priority -1. This package uses the SI spellings Hz, kHz, MHz, which do not clash. For ms and us the slot picks: with both packages, 5ms passed where an f64 goes is signal's number of seconds and where a Time goes this package's quantity. This package's ms and us sit at priority -2, so an untyped let t = 5ms; stays signal's number and adding this package never changes signal code; write 5μs or ms.of(5.0) for a quantity there. To leave the suffixes out, add the package with nabi add units --no-default-features --features ops.

Arrays

Quantity<Array<f64, R>, ..> is a whole array in one unit: km.array(a), the broadcast operators .+ .- .* ./ .< .>, .at(i), .sum(), .values_in(u). A number or a scalar quantity goes on either side (2.0 .* d, d ./ 2s, 2s .* v, 1.0 ./ t), and a chain of operators runs as one loop, as on bare arrays. Complex<f64> and f32 values work with the scalar operators.

use core::array::Array;
use units::kinds::Velocity;
use units::symbols::{m, s};

let d = m.array(Array::from_list([100.0, 200.0], [2]));
let t = s.array(Array::from_list([10.0, 25.0], [2]));
let v: Velocity<Array<f64, 1>> = d ./ t .+ 1m / 1s;   // one loop
println(v);                    // [11.0, 9.0] m/s
println(2s .* v);              // [22.0, 18.0] m

Accuracy and speed

Exact factors are exact doubles (ft is 0.3048, lbf 4.4482216152605 N); prefixes below one divide (1 / 1e3), so 1mm is the double nearest 0.001. Conversions round once or twice, about 1e-16 relative. Celsius and Fahrenheit convert in one exact step (20degC is exactly 68degF).

The dimension is only in the types, so quantity code runs as fast as bare f64: scalar code compiles to the same loop, and a chain of broadcast operators on quantity arrays fuses into one loop with no intermediate arrays, as on bare arrays. 1e7 values, nabi bench, one Apple M-series core:

Formulabare f64quantities
d[i] / t[i] + v0, summed in a counted loop5.66 ms5.66 ms
d ./ t .+ v0, arrays5.29 ms5.35 ms
m .* v .* v .* 0.5, arrays5.36 ms5.39 ms

Logarithmic units (decibel, neper) are not in this version.

Docs

https://packages.nabi-lang.org/packages/units/latest/docs

License

Licensed under either of MIT or Apache-2.0, at your option.

README 출처: github.com/nabi-lang/units, 커밋 7843fa91.